TITLE: CloudSystem Matrix Firmware Bundle for HPE Integrity BL860c/BL870c/BL890c i2 and i4 Servers (System, IO, OA and VC) – for HP Smart Update Manager

VERSION:
CloudSystem Matrix Bundle
Bundle Version: 7.5.1

HPE Integrity BL860c/BL870c/BL890c i2 Server System Bundle (27.00)
System Firmware Version: 1.98
FPGA Firmware Version: 2.05
iLO-3 Firmware Version: 01.57.07
Power Monitor Firmware Version: 03.04

HPE Integrity BL860c/BL870c/BL890c i4 Server System Bundle (46.01)
System Firmware Version: 02.63
FGPA Firmware Version: 02.02
iLO-3 Firmware Version: 01.70.01
Power Monitor Firmware Version: 03.04
Front Panel HW: 04.00 or 05.00
PRS HW: 02.08
IOH HW: 02.02

I/O smart components for HP-UX:
Firmware Flash Component for HPE Integrity BL8x0c i2 Server p410i (SAS): version 6.42 
Firmware Flash Component for HPE Integrity BL8x0c i4 Server p410i (SAS): version 6.42 
Firmware Flash Component for HPE Integrity BL8x0c i4 Server iocxgbe (NC553i embedded LOM)version 4.9.416.12

Firmware Flash Component for Add-in Smart Array adapters version 2013.09.25:
     
p711m: FW 6.42, EFI 3.58

Firmware Flash Component for Intel and Broadcom Adapters: version 2014.10.27 - installs at UEFI:     
      Warning: Use this smart component only if Broadcom IEXGBE-DRV version is lower than B.11.31.1303
          Intel NC360m, NC364m: EFI 4.3.02
          NC532m, NC532i HPE Integrity BL8x0c i2 Server embedded LOM: FW 6.2.28, EFI 5.2.60

Firmware Flash Component for Broadcom NIC HP-UX: 2014.2.18 - installs from HP-UX:
    Warning: Use this component for Broadcom NC532m only if IEXGBE-DRV version is B.11.31.1303 or later:
    NC532m: FW 6.2.28, EFI 5.2.60

Firmware Flash Component for HPE Integrity BL8x0c i2 Server LOM - HP-UX version 5.2.60: - installs from HP-UX:
    Warning: Use this component for HPE Integrity BL8x0c i2 Server NC532i only if IEXGBE-DRV version is B.11.31.1303 or later:
          NC532i embedded LOM: FW 6.2.28, EFI 5.2.60

Firmware Flash Component for Qlogic Fibre Channel Host Bus Adapters version 2014.02.14:
    8 Gb FC QMH2562 (451871-B21): EFI  2.27, FW 5.06.06
   
16 Gb FC SN1000Q PCIe (1-port, 2-port) B9F23A, B9F24A: EFI 6.13, FW 6.07.02 

Firmware Flash Component for Emulex Adapters Firmware for HPE Integrity servers version 2015.05.21(a):
    10 Gb 2-port FlexFabric NC551m, NC553m: ROM
4.9.416.12, LAN EFI 49.00a11, FC EFI  5.21.a13
    8 Gb FC LPe1205: ROM 2.02x2, EFI 4.01a5  
    NC552m: FW 4.9.416.12, LAN EFI 49.00a11


Onboard Administrator (OA)
OA Firmware Version: 4.50

Virtual Connect (VC)
VC Firmware Component Version: 4.45

HP Smart Update Manager (HP SUM)
HP SUM Version: 7.5.1

Note: 

DESCRIPTION:
This CloudSystem Matrix bundle contains the HP SUM application. This application contains the firmware for HPE Integrity BL860c/BL870c/BL890c i2 and HPE Integrity BL860c/BL870c/BL890c i4 Servers (System firmware (SFW), FPGA firmware, iLO-3 MP firmware and Power Monitor firmware), with I/O, VC and OA firmware).

Note:

For more information on HP SUM, review the HP SUM 7.5.1 User Guide and Release Notes.

UPDATE RECOMMENDATION: Recommended

[ ] Critical
        [ ] Panic, [  ] Hang, [ ] Abort, [ ] Corruption, [ ] Memory Leak
[  ] Hardware Enablement, [  ] Software Enablement
[X] Recommended 
[  ] Optional
        [ ] Hardware Enablement, [ ] Software Enablement, [X] non-critical
[ ] Initial Customer Release

SUPERSEDES:

CloudSystem Matrix Bundle
Bundle Version: 7.5.0.0(a)

PRODUCT MODEL(S):
HPE Integrity BL860c i2 Server
HPE Integrity BL870c i2 Server
HPE Integrity BL890c i2 Server
HPE Integrity BL860c i4 Server
HPE Integrity BL870c i4 Server
HPE Integrity BL890c i4 Server

OPERATING SYSTEMS:
HP-UX 11i v3 March 2010 Update (and later OE Releases) - For HPE Integrity BL860c/BL870c/BL890c i2 Server
HP-UX 11i v3 September 2012 Update and later (with Insight Management 7.1.2 patch) - For HPE Integrity BL860c/BL870c/BL890c i4 Server

LANGUAGES:
International English

ENHANCEMENTS 

Enhancements in iLO 1.68.08 (BL8x0c i4 version 46.00) and 1.57.07 (BL8x0c i2 version 27.00):

Note: For more information on these enhancements, refer to the latest HPE Integrity iLO 3 Operations Guide.

 

FIXES:

Fixes in iLO 01.70.01 (BL8x0c i4 version 46.01):

Fixes in iLO 01.68.08 (BL8x0c i4 version 46.00):

Fixes in SFW 02.63 (BL8x0c i4 version 46.00):

Fixes in iLO 1.57.07 (BL8x0c i2 version 27.00):

Fixes in SFW 1.98 (BL8x0c i2 version 27.00):

PREREQUISITES:

For latest dependencies on SAS IO, LOM, OA and VC, refer to this matrix:
integrity-release-sets

INSTALLATION INSTRUCTIONS:

Please review all instructions and the "Hewlett Packard Enterprise Support Tool License Terms" or your Hewlett Packard Enterprise support terms and conditions for precautions, scope of license, restrictions, and limitation of liability and warranties, before installing this package. It is important that you read and understand these instructions completely before you begin. This can determine your success in completing the firmware update.

Important Note: This version of HP SUM uses an Internet browser as the graphical user interface.  Currently supported browsers are:

Win2k8

Win2012

Win7

Win8

SLES11

SLES12

RHEL6

RHEL7

IE 9, 10 or 11

x

x

x

x

 

 

 

 

FireFox 17 ESR

x

x

x

x

FireFox 18 or later

x

x

x

x

Chrome 24 or later

x

x

x

x

x

x

x

x

Important Note: HP SUM now uses port 63001 by default for pulling FW files from the server running HP SUM. 

A. Extracting and Running HP SUM

  1. Download the firmware bundle binary <filename>.exe or <filename>.tar.gz in a new folder on your system.
  2. Extract the bundle:
  3. The above steps will extract the contents of the bundle in the new folder where the bundle file is located. HP SUM and firmware components will reside in the same folder.
  4. Execute hpsum.bat (Windows) or hpsum.sh (Linux), located in the extracted folder, by logging as a user with Administrator or root privilege.  Executing hpsum will bring up a graphical user interface of the HP Smart Update Manager (HP SUM).

NOTE: HP SUM also provides a Command Line Interface (CLI) that allows user to perform scripted installations in silent mode. For more information please refer to the HP SUM User Guide located at www.hpe.com/info/hpsum/documentation or the "CLIHelp.txt" file in the extracted folder.

B. Installing the Firmware Components using HP SUM - Graphical User Mode

1.     Welcome Screen:

2.     For local updates on a Windows or Linux node, use Localhost Guided Update:

3.     For remote OA, Superdome 2 OA and iLO nodes

4.     For remote Windows, Linux, HP-UX and VMware nodes

Refer to the HP SUM User Guide for more information.

HP SUM KNOWN ISSUES:

            To resolve this issue, enable the port traffic associated with the HP SUM application by performing the following steps:

1.    Bring up McAfee Host Intrusion Prevention

2.    Select the Activity Log tab. Notice the entry in the Message column similar to the following: Blocked Incoming TCP from the HOST (x.x.x.x) during execution of HP SUM.

3.    Select the Firewall Policy tab.

4.    On the bottom of the screen, click Add (Add new rule).

5.    Use the following settings for the new firewall rules on your system.
Action: Permit
Protocol: IP - TCP
Direction: Incoming
Local Service: Single - 63001
Remote Service: Range From: 1024 - To: 65535
Address: Any Active

6.    Click OK to ensure new firewall rules have been implemented.

7.    Restart HP SUM.

Refer to the HP SUM 7.5.1 Release Notes for a complete list of known HP SUM installation issues.

COMPATIBILITY/INTEROPERABILITY:

DETERMINING CURRENT VERSION
HP SUM displays the current version of the firmware on iLO hosts in the final install log. However user can also log in to the iLO-3 MP and use the following procedure to find out the current firmware versions.

  1. Establish a telnet session with the iLO-3 MP.
  2. Logon to the iLO-3 MP using the Administrator password.
  3. Type "CM" to enter the Command Menu.
  4. Type "SYSREV" to display system revision information. The following should be displayed if the current firmware is installed.

 SYSREV 

For HPE Integrity BL860c/BL870c/BL890c i2
 Revisions               Active         Pending
  -------------------------------------
 iLO FW                :  01.57.07
 System FW          :  1.98
 MHW FPGA         :  02.05
 Power Mon FW     :  03.04
 Front Panel HW    :  04.00 (or 02.00 or 03.00 are acceptable)
 PRS HW              :  02.07 (or 02.06 is acceptable)
 IOH HW               :  02.02 (or 1.02, 1.03, and 2.00 are also acceptable)

For HPE Integrity BL860c/BL870c/BL890c i4
    Revisions            Active    Pending
    ---------------------------------------------------

     iLO FW             : 01.70.01
     System FW        : 02.63
     MHW FPGA      : 02.02
     Power Mon FW  : 03.04
     Front Panel HW : 04.00   02.00, 03.00 and 5.00 are also acceptable
     PRS HW           : 02.08   02.06 and 02.07 are also acceptable
     IOH HW           : 02.02   1.02, 1.03, and 02.00, are also acceptable

KNOWN FIRMWARE ISSUES:

SFW (HPE Integrity BL8x0c i2 and i4 servers):

iLO (HPE Integrity BL8x0c i2 and i4 servers):

KNOWN FIRMWARE UPDATE ISSUES:

KNOWN I/O FIRMWARE ISSUES:

DISCLAIMER:
The information in this document is subject to change without notice.

Hewlett Packard Enterprise makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett Packard Enterprise shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.

This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be reproduced, photocopied, or translated to another language without the prior written consent of Hewlett Packard Enterprise Company.

(C) Copyright 1994-2016 Hewlett Packard Enterprise Development Company, L.P.

FEEDBACK 
As we are continuing to improve the firmware management process we welcome your feedback on this document and on the firmware update process: TEAM-FWupdateFeedback@groups.ext.hpe.com

SUPERSEDES HISTORY:

Bundle Version 7.5.0:

ENHANCEMENTS 

FIXES:

Fixes in iLO 01.67.04:

Fixes in I/O components included in this bundle:

Fixes in LOM 4.9.416.12 and in Emulex Adapters Firmware version 2015.05.21:

Fixes in SAS p410i FW 6.42:   

Bundle version 7.4.1.0:

Fixes:

Enhancements:

Bundle version 7.4.0:

Enhancements:

iLO 1.56.02:

For a complete list of fixes and enhancements for OA and VC, please refer to

For more information on HP CloudSystem Matrix 7.4.0 fixes, updates and enhancements, please refer to the CloudSystem Matrix Release notes & Compatibility Chart

Fixes in BL8x0c i2 firmware version 26.41:

FPGA 2.05:

iLO 1.56.02: 

SFW 1.97: 

Fixes in IO components included in this bundle:

Fixes in Qlogic Fibre Channel Host Bus Adapters firmware version 2014.02.14:

Fixes in Intel and Broadcom Adapters Firmware version 2014.04.21:

Fixes in Broadcom NIC HP-UX version 2014.2.18 and HP Integrity BL8x0c i2 LOM EFI version 5.2.60:

Fixes in SAS FW 6.42:   

Fixes in Emulex Adapters firmware version  2013.05.02:


For a complete list of fixes and enhancements for OA and VC, please refer to

For more information on HP CloudSystem Matrix 7.4.0 fixes, updates and enhancements, please refer to the CloudSystem Matrix Release notes & Compatibility Chart

Bundle version 7.3.2.0:

For a complete list of fixes and enhancements, please refer to

 

Bundle version: 7.3.1.0(b):

FIXES:
Virtual Connect fixes in VC 4.10(b):

Onboard Administrator fixes in OA 4.12:

Bundle Version: 7.2.0.1:

ENHANCEMENTS 

 UEFI Driver 5.2.59 (from 5.2.58) for embedded LOM, NC532m:

FIXES:

iLO 01.61.04 (BL8x0c i4 43.01) and iLO 1.55.02 (BL8x0c i2 26.36):

Other issues fixed in iLO 1.55.02 (BL8x0c i2 26.36): 

Fixes in SFW 1.95 (BL8x0c i2 26.36):

Boot Code 6.2.25 (from 6.2.21) for embedded LOM, NC532m:

LPe1205 HBA FW version 2.02x2 (from 2.00a4):

Bundle Version: 7.1.1.3:

ENHANCEMENTS / FIXES:

HP Integrity BL860c/BL870c/BL890c i4 Server System / iLo firmware:
Support added to CloudSystem Matrix (CSM) 7.1.1 environment

Virtual Connect:
Please refer to the
VC 3.70 Release notes for fixes and enhancements.

Onboard Administrator:
Please refer to the
OA 3.60 Release notes for fixes and enhancements.

For more information on HP CloudSystem Matrix 7.1.1.3 fixes, updates and enhancements, please refer to the CloudSystem Matrix Release notes & Compatibility Chart

Bundle Version 7.1.1(a):

Server FW: 26.34

SFW / ILO:

Virtual Connect:

Please refer to the VC 3.70 Release notes for fixes and enhancements.

Onboard Administrator:
Please refer to the 
OA 3.60 Release notes for fixes and enhancements. 

Bundle Version 7.1.1:

Server FW: 26.33

Virtual Connect:
Please refer to the 
VC 3.70 Release notes for fixes and enhancements.

Onboard Administrator:
Please refer to the 
OA 3.60 Release notes for fixes and enhancements. 

Bundle Version 7.1(a) / 7.0(a):

Virtual Connect: 
Please refer to the 
VC 3.60 Release notes for fixes and enhancements. 

Onboard Administrator: 
Please refer to the 
OA 3.56 Release notes for fixes and enhancements.

Server FW: 26.33:

System / iLo firmware (1.53.02):

Enhancements:

Fixes: