TITLE: CloudSystem Matrix Firmware Bundle for HPE Integrity
BL860c/BL870c/BL890c i2 and i4 Servers (System, IO, OA and
VC) – for HP Smart Update Manager
VERSION:
CloudSystem Matrix Bundle
Bundle Version: 7.5.1
HPE Integrity BL860c/BL870c/BL890c i2 Server System Bundle (27.00)
System Firmware Version: 1.98
FPGA Firmware Version: 2.05
iLO-3 Firmware Version: 01.57.07
Power Monitor Firmware Version: 03.04
HPE Integrity BL860c/BL870c/BL890c i4
Server System Bundle (46.01)
System Firmware Version: 02.63
FGPA Firmware Version: 02.02
iLO-3 Firmware Version: 01.70.01
Power Monitor Firmware Version: 03.04
Front Panel HW: 04.00 or 05.00
PRS HW: 02.08
IOH HW: 02.02
I/O smart components for HP-UX:
Firmware Flash Component for HPE Integrity BL8x0c i2 Server p410i
(SAS): version 6.42
Firmware Flash Component for HPE Integrity BL8x0c i4 Server p410i
(SAS): version 6.42
Firmware Flash Component for HPE Integrity BL8x0c i4 Server iocxgbe (NC553i
embedded LOM): version 4.9.416.12
Firmware Flash Component for Add-in Smart
Array adapters version 2013.09.25:
p711m: FW 6.42, EFI 3.58
Firmware Flash Component for Intel and Broadcom Adapters: version
2014.10.27 - installs at UEFI:
Warning: Use this smart component only
if Broadcom IEXGBE-DRV version is lower than B.11.31.1303
Intel NC360m, NC364m:
EFI 4.3.02
NC532m, NC532i HPE
Integrity BL8x0c i2 Server embedded LOM: FW 6.2.28, EFI 5.2.60
Firmware Flash Component for Broadcom NIC
HP-UX: 2014.2.18 - installs from HP-UX:
Warning: Use this component for Broadcom NC532m
only if IEXGBE-DRV version is B.11.31.1303 or later:
NC532m: FW 6.2.28, EFI 5.2.60
Firmware Flash Component for HPE Integrity BL8x0c i2 Server LOM - HP-UX
version 5.2.60: - installs from HP-UX:
Warning: Use this component for HPE Integrity
BL8x0c i2 Server NC532i only if IEXGBE-DRV version is B.11.31.1303 or
later:
NC532i embedded LOM:
FW 6.2.28, EFI 5.2.60
Firmware Flash Component for Qlogic Fibre
Channel Host Bus Adapters version 2014.02.14:
8 Gb FC QMH2562 (451871-B21): EFI 2.27,
FW 5.06.06
16 Gb FC SN1000Q PCIe (1-port, 2-port) B9F23A, B9F24A:
EFI 6.13, FW 6.07.02
Firmware Flash Component for Emulex Adapters Firmware for HPE Integrity
servers version 2015.05.21(a):
10 Gb 2-port FlexFabric NC551m, NC553m: ROM 4.9.416.12, LAN EFI 49.00a11, FC EFI 5.21.a13
8 Gb FC LPe1205:
ROM 2.02x2,
EFI 4.01a5
NC552m:
FW 4.9.416.12, LAN EFI 49.00a11
Onboard Administrator (OA)
OA Firmware Version: 4.50
Virtual Connect (VC)
VC Firmware Component Version: 4.45
HP Smart Update Manager (HP SUM)
HP SUM Version: 7.5.1
Note:
- HP SUM 5.3.0 introduced the capability to update IO firmware
using HP SUM on integrity servers running HP-UX 11i v3. However due to a hang issue when updating p410i SAS IO
from 5.82 to another version with HP SUM, the built-in p410i SAS IO on
BL8x0c i4 blades must continue to be updated using alternate methods (EFI
applications, ISO images, ...). All
other IO components, included in this bundle, can be updated using HP
SUM.
- If a system FW update is pending, it will be activated at
next server power off, and server can be powered on only after the
firmware activation completes. To verify if a
system FW update is pending, run the iLO3 MP “SYSREV” command and check if
the Pending column shows any version for “System FW”.
- Warning: If you reset
the system while the SFW update is pending, the server may not be able to
reboot due to a firmware mismatch between SFW and iLO. If that’s the
case, power off the server to enable the new SFW activation and then
power the server back on after activation is complete.
- While
the server is powered off, you can monitor the progress of the system
firmware activation by running the iLO3 MP “FW” command from the Command
Menu (CM).
DESCRIPTION:
This CloudSystem Matrix bundle contains
the HP SUM application. This application contains the firmware for HPE
Integrity BL860c/BL870c/BL890c i2 and HPE Integrity BL860c/BL870c/BL890c i4
Servers (System firmware (SFW), FPGA firmware, iLO-3 MP firmware and Power
Monitor firmware), with I/O, VC and OA firmware).
Note:
- Any update to the information below will be available in the
release notes for CloudSystem Matrix Firmware Bundle for HPE Integrity
BL860c/BL870c/BL890c i2 and BL860c/BL870c/BL890c i4 Server (System, IO,
OA, and VC firmware) – HP SUM available on http://www.hpe.com/
- For HPE Integrity BL860c/BL870c/BL890c i2 Servers, SAS
RAID firmware (version 6.42) and LAN-On-Motherboard (LOM) firmware
(version 5.2.60) must be installed on your server along with this
CloudSystem Matrix Firmware Bundle.
- For HPE Integrity BL860c/BL870c/BL890c i4 Servers, SAS
RAID firmware (version 6.42) and LAN-On-Motherboard (LOM) firmware
(version 4.9.416.12) must be installed on your server along with
this CloudSystem Matrix Firmware Bundle. Current
versions can be checked using the HP-UX commands “ioscan -kfnd ciss”,
“sautil /dev/cissx vpd” and “nwmgr -q vpd -c lan0”
For more information on HP SUM, review the HP
SUM 7.5.1 User Guide and Release Notes.
UPDATE RECOMMENDATION: Recommended
[ ] Critical
[ ] Panic, [ ] Hang, [ ]
Abort, [ ] Corruption, [ ] Memory Leak
[ ] Hardware Enablement, [ ] Software Enablement
[X] Recommended
[ ] Optional
[ ] Hardware Enablement, [ ]
Software Enablement, [X] non-critical
[ ] Initial Customer Release
SUPERSEDES:
CloudSystem Matrix Bundle
Bundle Version: 7.5.0.0(a)
PRODUCT MODEL(S):
HPE Integrity BL860c i2 Server
HPE Integrity BL870c i2 Server
HPE Integrity BL890c i2 Server
HPE Integrity BL860c i4 Server
HPE Integrity BL870c i4 Server
HPE Integrity BL890c i4 Server
OPERATING SYSTEMS:
HP-UX 11i v3 March 2010 Update (and later
OE Releases) - For HPE Integrity BL860c/BL870c/BL890c i2 Server
HP-UX 11i v3 September 2012 Update and later (with Insight Management
7.1.2 patch) - For HPE Integrity BL860c/BL870c/BL890c i4 Server
LANGUAGES:
International English
ENHANCEMENTS
Enhancements in iLO 1.68.08 (BL8x0c i4 version
46.00)
and 1.57.07 (BL8x0c i2 version 27.00):
- Users
can now configure a security banner message to be displayed in the iLO
login screen.
- iLO
now enables users to configure an idle session timeout for web based user
interface.
- An
option is now provided in Integrity iLO3 to "Enforce AES/3DES"
ciphers for network encryption.
- Users
are now able to create a custom CSR (Certificate Signing request) and
import a third party signed SSL certificate into iLO for secure iLO webGUI
access.
Note: For more information
on these enhancements, refer to the latest HPE Integrity iLO 3 Operations
Guide.
FIXES:
Fixes in iLO
01.70.01 (BL8x0c i4 version 46.01):
- Upon A/C power cycle or insertion of BL8x0c
i4 blades (AM377A), iLO3 on newer system boards running iLO firmware
version 1.68.08 or lower would log a false fatal event CPU_VCCIO_CONFIG_FALURE,
causing the health LED to go amber until the system is powered on. This is
now fixed.
Fixes in iLO 01.68.08 (BL8x0c i4 version 46.00):
- Addressed the OpenSSL Poodle (Padding
Oracle on Downgraded Legacy Encryption) vulnerability CVE-2014-3566 in iLO. Note: SSLv3 based
connections to iLO webGUI are now disabled.
- Users can now successfully access the iLO3
GUI using firefox version 23 or above.
- iLO will now allow two simultaneous telnet
connection attempts and five simultaneous SSH connection attempts.
- A Telnet session to iLO would rarely hang
during an operation such as FPL dump where continuous stream of data
was being sent by iLO to the client. This is now fixed.
- Fixed an issue where system firmware would
occasionally de-configure one or more DIMMs reporting DIMM SPD
Checksum errors due to a timeout during AC power cycle of the system.
- Disabled export cipher encryption in iLO3.
Fixes in SFW 02.63 (BL8x0c i4 version 46.00):
- In an HPE Virtual Machine (HPVM)
environment, the OS would rarely fail to capture CMC and MCA error logs.
This is now fixed.
- A server containing a PCI card which does
not support PCI extended capability would sometimes hang without
any error message while handling an MCA. This is now fixed.
Fixes in iLO 1.57.07 (BL8x0c i2 version 27.00):
- Addressed the OpenSSL Poodle (Padding
Oracle on Downgraded Legacy Encryption) vulnerability CVE-2014-3566 in iLO. Note: SSLv3 based
connections to iLO webGUI are now disabled.
- Users can now successfully access the iLO3
GUI using Firefox version 23 or above.
- iLO will now allow two simultaneous telnet
connection attempts and five simultaneous SSH connection attempts.
- Fixed an issue where system firmware would
occasionally de-configure one or more DIMMs reporting DIMM SPD Checksum
errors due to a timeout during AC power cycle of the system.
- Disabled export cipher encryption in iLO3.
Fixes in SFW 1.98 (BL8x0c i2 version 27.00):
- In
an HPE Virtual Machine (HPVM) environment, the OS would rarely fail to
capture CMC and MCA error logs. This is now fixed.
PREREQUISITES:
- HPE CloudSystem Matrix 7.5.1 requires
OA version 4.50 and VC component version 4.45
for HPE Integrity BL860c/BL870c/BL890c i2 and BL860c/BL870c/BL890c i4
servers.
- NOTE: OA version 4.50 will act as
a bridge release for customers who want to upgrade from
versions prior to 4.50 to versions expected after version 4.50. Hence, customers are expected to
update to OA 4.50 before they upgrade to future OA recipes.
- The VC firmware can be updated using the
HP SUM version included in this bundle. It can also be updated using the
Virtual Connect Support Utility (VCSU). VCSU version 1.11.1 or later
is required. The VCSU utility is not included in this bundle and may be
found on the HPE Support & Drivers web site.
- iLO-3 MP(s) must be on the network
(reachable from local system) and have static IP or be configured with
DHCP.
- An http daemon, service or IDS (Intrusion
Detection System) running in the local system may interfere with HP SUM
connecting to remote hosts, hence these services may need to be disabled
when HP SUM is running.
- Refer
to the HP Smart Update Manager 7.5.1 User Guide and Release Notes for any
prerequisites required for HP SUM.
For latest dependencies on SAS IO, LOM, OA
and VC, refer to this matrix:
integrity-release-sets
INSTALLATION INSTRUCTIONS:
Please review all instructions and the "Hewlett
Packard Enterprise Support Tool License Terms" or your Hewlett Packard
Enterprise support terms and conditions for precautions, scope of license,
restrictions, and limitation of liability and warranties, before installing
this package. It is important that you read and understand these instructions
completely before you begin. This can determine your success in completing the
firmware update.
Important
Note: This version of HP
SUM uses an Internet browser as the graphical user interface.
Currently supported browsers are:
|
Win2k8
|
Win2012
|
Win7
|
Win8
|
SLES11
|
SLES12
|
RHEL6
|
RHEL7
|
IE 9, 10 or 11
|
x
|
x
|
x
|
x
|
|
|
|
|
FireFox 17 ESR
|
|
|
|
|
x
|
x
|
x
|
x
|
FireFox 18 or later
|
x
|
x
|
x
|
x
|
|
|
|
|
Chrome 24 or later
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Important Note: HP SUM now uses port 63001 by default for pulling FW
files from the server running HP SUM.
A. Extracting and Running HP SUM
- Download
the firmware bundle binary <filename>.exe or <filename>.tar.gz
in a new folder on your system.
- Extract
the bundle:
- Windows:
double click <filename>.exe then click “Extract”
- Linux:
gunzip <filename>.tar.gz; tar -xvf <filename>.tar
- The
above steps will extract the contents of the bundle in the new folder
where the bundle file is located. HP SUM and firmware components will
reside in the same folder.
- Execute
hpsum.bat (Windows) or hpsum.sh (Linux), located in the extracted folder, by
logging as a user with Administrator or root privilege. Executing
hpsum will bring up a graphical user interface of the HP Smart Update Manager
(HP SUM).
NOTE: HP SUM also provides a Command Line Interface (CLI) that allows user
to perform scripted installations in silent mode. For more information please
refer to the HP SUM User Guide located at www.hpe.com/info/hpsum/documentation or the "CLIHelp.txt" file in the
extracted folder.
B. Installing the Firmware Components
using HP SUM - Graphical User Mode
1. Welcome Screen:
- Once started, a page displays with HP SUM
main content on it.
2. For local updates on a
Windows or Linux node, use Localhost Guided Update:
- Select Localhost Guided Update from the
main content window
- Choose Interactive or Automatic mode
- Continue to step through the process of
completing the inventory of the baseline, inventory of the node and
deployment of updates to the localhost node.
- Note: You must have components in
the same directory as HP SUM in order for the baseline to be added during
Localhost Guided Update.
3. For remote OA,
Superdome 2 OA and iLO nodes
- Select Baselines from the main content
menu
- Verify that the current directory
baseline completes inventory
- Select Nodes from the main content menu
- Select 'Add Node' and enter IP address
and credentials for the Onboard Administrator, select the Baseline to be
assigned from the Baseline drop down, and click 'Add'
- After initial verification of credentials
is done, click Inventory from the Actions menu
- After Inventory is done on the OA, iLO
nodes will be added automatically and Inventory started on them.
- If a Virtual Connect node was found,
click on that node and enter credentials which will start inventory
- Once inventory is done on all OA, VC and
iLO nodes, click on the OA node and start Review/Deploy
- On the Review page, click to select the
associated nodes to update along with the OA. HP SUM will sequence
the updates as needed.
- Start the Deploy
- After Deploy is done, the logs for the
updates can be reviewed on each node page
4. For remote Windows,
Linux, HP-UX and VMware nodes
- Select Nodes from the main content
- Verify that the current directory
baseline completes inventory
- Select Nodes from the main content menu
- Select 'Add Node' and enter IP address
and credentials for the remote node, select the Baseline to be assigned
from the Baseline drop down, and click 'Add'
- After initial verification of credentials
is done, click Inventory from the Actions menu
- After Inventory is done on the node,
click Review/Deploy from the Actions menu
- Review the updates to be applied and make
changes to installation options as needed
- Start Deploy
- After Deploy is done, the logs for the
updates can be viewed on the node page
Refer to the HP
SUM User Guide for more
information.
HP SUM KNOWN ISSUES:
- HP SUM fails on Windows due to McAfee
firewalls. This is a known issue with McAfee that McAfee firewalls block
HP SUM traffic.
To resolve this issue, enable the port traffic associated with the HP SUM
application by performing the following steps:
1. Bring up McAfee Host
Intrusion Prevention
- Windows Vista: From the system tray,
click the McAfee icon -> Manage Features -> Host Intrusion
Prevention
- Windows 7: From the system tray, right
click Host Intrusion Prevention icon -> Configure
2. Select the Activity Log
tab. Notice the entry in the Message column similar to the following: Blocked
Incoming TCP from the HOST (x.x.x.x) during execution of HP SUM.
3. Select the Firewall
Policy tab.
4. On the bottom of the
screen, click Add (Add new rule).
5. Use the following
settings for the new firewall rules on your system.
Action: Permit
Protocol: IP - TCP
Direction: Incoming
Local Service: Single - 63001
Remote Service: Range From: 1024 - To: 65535
Address: Any Active
6. Click OK to ensure new
firewall rules have been implemented.
7. Restart HP SUM.
Refer to the HP
SUM 7.5.1 Release Notes for a complete
list of known HP SUM installation issues.
COMPATIBILITY/INTEROPERABILITY:
- WARNING: Do not disconnect AC power to HPE
Integrity Servers or remove HPE Server Blades from the enclosure during
the firmware upgrade process. Doing so may corrupt the programming of the
firmware, rendering the Server inoperable
DETERMINING CURRENT VERSION
HP SUM displays the current version of
the firmware on iLO hosts in the final install log. However user can also log
in to the iLO-3 MP and use the following procedure to find out the current
firmware versions.
- Establish
a telnet session with the iLO-3 MP.
- Logon
to the iLO-3 MP using the Administrator password.
- Type
"CM" to enter the Command Menu.
- Type
"SYSREV" to display system revision information. The following
should be displayed if the current firmware is installed.
SYSREV
For HPE Integrity BL860c/BL870c/BL890c
i2
Revisions Active Pending
-------------------------------------
iLO
FW : 01.57.07
System FW : 1.98
MHW FPGA : 02.05
Power Mon FW : 03.04
Front Panel HW : 04.00 (or 02.00 or 03.00 are acceptable)
PRS HW
: 02.07 (or
02.06 is acceptable)
IOH HW
: 02.02 (or
1.02, 1.03, and 2.00 are also acceptable)
For HPE Integrity BL860c/BL870c/BL890c
i4
Revisions
Active Pending
---------------------------------------------------
iLO FW
: 01.70.01
System FW : 02.63
MHW FPGA : 02.02
Power Mon FW : 03.04
Front Panel HW : 04.00 02.00, 03.00 and
5.00 are also acceptable
PRS HW :
02.08 02.06 and 02.07 are also acceptable
IOH HW :
02.02 1.02, 1.03, and 02.00, are also acceptable
KNOWN FIRMWARE ISSUES:
SFW (HPE
Integrity BL8x0c i2 and i4 servers):
- DDDC (Double Device Data Correction) will
not be invoked for a second DRAM failure in certain cases when excessive
single bit memory errors are observed. This will be indicated by a WBEM
Event 7000. There is no impact to customer applications however it is
recommended to service the DIMM upon seeing this event as the server will
stop correcting single bits memory errors if one more DRAM in the same
rank fails.
iLO (HPE Integrity
BL8x0c i2 and i4 servers):
- Java based Virtual Media Applet and Java
based Remote Serial Console applet will not be launched on clients
running Java 7 update 51 (see advisory c04089818).
KNOWN FIRMWARE UPDATE
ISSUES:
- Bl8x0c i2 systems updating from firmware
version 21.08 or earlier (iLO version 1.30.30 or earlier) to version
26.41 (2014.09) will encounter the error “This package is not
supported for this hardware”.
Workaround: Update
first to 26.36 (iLO version 1.55.02) before updating to 26.41 (2014.09).
- During firmware installation using HP SUM
7.5.1, at the end of deployment, the system may power off instead of
rebooting, even though "Always" was selected as reboot option.
Workaround: If the system remains in power off state after
deployment completes, you may need to restart it manually. Note:
The new firmware should have installed correctly. This will be fixed in a
future version of HP SUM.
- Refer to the HP SUM 7.5.1 Release notes for complete list of
known HP SUM installation issues.
KNOWN I/O FIRMWARE
ISSUES:
- Online firmware update may fail for newer
Qlogic 8 GB FC cards with the error: "Error: ROM programming was unsuccessful".
Workaround: HPE recommends updating these FC cards using the EFI
bundle instead. The EFI bundle is available at http://www.hpe.com/support/hpesc; enter
the card product name, select the Operating System “OS Independent”, then
category "EFI".
Note: This issue exists in driver version FibrChanl-01
B.11.31.1503 or earlier and is fixed in driver version FibrChanl-01
B.11.31.1506.
DISCLAIMER:
The information in this document is
subject to change without notice.
Hewlett Packard Enterprise makes no
warranty of any kind with regard to this material, including, but not limited
to, the implied warranties of merchantability and fitness for a particular
purpose. Hewlett Packard Enterprise shall not be liable for errors
contained herein or for incidental or consequential damages in connection with
the furnishing, performance, or use of this material.
This document contains proprietary
information that is protected by copyright. All rights are reserved. No part of
this document may be reproduced, photocopied, or translated to another language
without the prior written consent of Hewlett Packard Enterprise Company.
(C) Copyright 1994-2016 Hewlett Packard
Enterprise Development Company, L.P.
FEEDBACK
As we are continuing to improve the
firmware management process we welcome your feedback on this document and on
the firmware update process: TEAM-FWupdateFeedback@groups.ext.hpe.com
SUPERSEDES HISTORY:
Bundle Version 7.5.0:
ENHANCEMENTS
FIXES:
Fixes in iLO 01.67.04:
Fixes in I/O components included in this bundle:
Fixes in LOM 4.9.416.12 and in Emulex
Adapters Firmware version 2015.05.21:
- Fixes in
Emulex Firmware 4.9.416.12 (from 4.2.401.2212):
- When ISL (Inter-Switch Link) is disabled
to remote site, local storage access is also lost
- The EFI device manager does not display
all the AT118A cards present on Superdome 2 servers
- IOCXGBE: Pause frame storm seen under DEAD
state condition
- IOCXGBE :Flow control behavior is not
functioning as expected
- Link status is shown as DOWN in HP-UX
& HII (Human Interface Infrastructure) though the interface is UP in
OA
Fixes in SAS p410i FW 6.42:
- Resolved an issue
where, after doing a mode toggle at EFI ORCA, the controller name would
not be displayed when running the command: “reconnect -r”
- Added a new POST
message 1813 to indicate bad or failed battery charge circuit
- No longer display
a POST error message 1805 “Cache Module Super-Cap is not installed” when
the controller is configured to work without super-capacitors
Bundle version 7.4.1.0:
Fixes:
- No changes were
made in the HP Integrity server firmware or I/O firmware.
- HP SUM 7.2.1 fixed
the following issue:
- HP SUM did not add FIPS enabled VC nodes.
Enhancements:
- No changes were made in the HP Integrity
servers or I/O firmware.
Bundle version 7.4.0:
Enhancements:
iLO 1.56.02:
- Improved
console performance from iLO version 1.55.02
For a complete list of fixes and
enhancements for OA and VC, please refer to
For more information
on HP CloudSystem Matrix 7.4.0 fixes, updates and enhancements, please refer to
the CloudSystem Matrix Release notes & Compatibility
Chart
Fixes in BL8x0c i2 firmware version 26.41:
FPGA 2.05:
- In rare occasions,
when trying to power on a blade on an HP Integrity BL8x0c i2 server in
multi-blade configuration, with all blade enclosures powered off (AC on/DC
off), the blade may fail to power on. This is now fixed.
iLO 1.56.02:
- Fixed SSL/TLS MITM
vulnerability (CVE-2014-0224).
- Fixed an issue
where a Telnet session to iLO would sometimes hang during an operation
such as FPL dump where a continuous stream of data is being sent by
iLO to the client. System and iLO would however continue to function
normally.
SFW 1.97:
- Fixed an issue
where a server with a controller configured in HBA mode would sometimes
hang at boot time without any error messages if a Hard Disk configured for
RAID mode was put into the server without previously removing the Hard
Disk's RAID metadata.
- Boot from boot
manager may no longer fail after a VC profile has been unassigned and
reassigned.
- A server
containing a PCI card which does not support PCI extended
capability would sometimes hang without any error message while
handling an MCA. This issue is now fixed.
- Fixed an issue
where, on rare occasions, the following series of events would be seen in
the SEL (System Event Log) during POST (Power-On Self-Test): a
MEM_MEM_TEST_FAILED level 3 event, a SYSTEM_SOFT_RESET, an
EFI_LAUNCH_BOOT_MANAGER. These errors did not reflect a real
hardware failure if the MEM_MEM_TEST_FAILED and soft reset
incident were not accompanied by an MCA or other errors.
Fixes in IO components included in this bundle:
Fixes in Qlogic Fibre Channel Host Bus Adapters firmware
version 2014.02.14:
- Qlogic EFI
2.27 (from
2.22):
- The
QMH2562 card would sometimes report VC_CLP_RESP_DEV_NVM_ERR when no
Interconnect module was connected or when it was connected to a particular
4Gb FC switch. This issue is now fixed.
- Qlogic FW
5.06.06 (from 5.03.15):
- Fixed
a link failover issue in Qlogic 8Gb firmware for the 8Gb Mezzanine Fibre
channel adapter attached to HP VC 24 port module.
Fixes in Intel and Broadcom Adapters Firmware version
2014.04.21:
- Firmware
version 6.2.28 (Changes from 6.2.25):
- LOM
and IOX-LAN cards may transmit excessive pause frames during MCA process
in Superdome 2 Platform multi-function mode.
- Intel EFI
version 4.3.02 (from 4.3.01):
- NIC
EFI driver update was failing on some cards shipped with a flash memory
chip (Atmel 25DF041A) that did not support the EFI driver. EFI driver
version 4.3.02 fixes this issue.
Fixes in Broadcom NIC HP-UX version 2014.2.18 and HP
Integrity BL8x0c i2 LOM EFI version 5.2.60:
- Firmware
version 6.2.28 (Changes from 6.2.25):
- IOX-LAN
cards may transmit excessive pause frames during MCA process in Superdome
2 Platform multi-function mode.
Fixes in SAS FW 6.42:
- Resolved an
issue where, after doing a mode toggle at EFI ORCA, the controller name
would not be displayed when running the command: “reconnect -r”
- Added a new POST
message 1813 to indicate bad or failed battery charge circuit
- No longer
display a POST error message 1805 “Cache Module Super--Cap is not
installed” when the controller is configured to work without
super-capacitors
Fixes in Emulex Adapters firmware version 2013.05.02:
- Firmware
4.2.401.2212 (from 4.1.450.14):
- Critical: As the result of
auto negotiation failure, the connection between LOM and ProCurve 6120XG
may link up at 1Gbps instead of 10Gbps. This occurs intermittently (as
often as once in 10 retries) after executing "Reset Server blade
#" from the OA CLI. Affected Products: All BE3 based Cards and LOMs.
This is also seen with 10G passthrough Interconnect module.
- Boot
failure might be seen after running commands "reconnect -r",
"map -r" commands at EFi environment.
- Boot
from SAN intermittently fails during EFI bootstrap of a FCoE device that
is busy.
- FCOE
EFI version truncated in VPD data that is displayed by ODE-FCFUPDATE tool
at EFI.
- On
HP-UX the fcoc port driver state is displayed as AUTHENTICATION/DISCOVERY
when fcocutil command is run to check the port information
- NIC
EFI driver 2.22.a1 (from 2.21.ac):
- Reset
to Defaults restores wrong power configuration. Reset to Default is issued
from Device Manager->Emulex 10G NIC-> R/r or Erase Configuration;
Symptom: Restoring the defaults shows an HP unsupported option:
MultiChannel Option
For a complete list of fixes and enhancements for OA and VC, please refer
to
For more information on HP CloudSystem Matrix
7.4.0 fixes, updates and enhancements, please refer to the CloudSystem Matrix Release notes & Compatibility
Chart
Bundle version 7.3.2.0:
For a complete list of fixes and
enhancements, please refer to
Bundle version: 7.3.1.0(b):
FIXES:
Virtual Connect fixes in
VC 4.10(b):
- OpenSSL used by
VC was modified to address vulnerability to CVE-2012-2110 and
CVE-2012-2131
Onboard Administrator fixes in OA 4.12:
- Fixed an issue
where, on rare occasions, a SSH session to iLO from OA,
established within a few minutes of an iLO reboot using the
‘connect server’ command, would get disconnected unexpectedly. Connection
could be re-established to resume normal operation.
- Disabled support
for OpenSSL TLS heartbeat extension (CVE-2014-0160).
See HPSBMU02994 for more
details.
Bundle Version: 7.2.0.1:
ENHANCEMENTS
UEFI Driver 5.2.59 (from 5.2.58)
for embedded LOM, NC532m:
- Added
Dynamic Network detection support
FIXES:
iLO 01.61.04 (BL8x0c i4 43.01) and
iLO 1.55.02 (BL8x0c i2 26.36):
- Fixed
a security vulnerability issue that exists in HP Integrated Lights-Out
(iLO 3) version 1.60.07 for BL8x0c i4 and versions 1.53.02 and lower for
BL8x0c i2. The vulnerability could be remotely exploited resulting in
disclosure of information. See SSRT100934 for more details.
- When
the serial port MUX is set to “Persistent AUX” mode and the server is A/C
power cycled, the serial port MUX will retain the “persistent AUX” mode
setting and will not reset to “iLO” mode.
- The
severity of the events “VOLTAGE_FAULT and VOLTAGE_LOW_CRITICAL” have
been increased so that power supply events in SFM such as
"power supply failed or disconnected" and "power
supply AC lost" will now be reported in HP-UX syslog for easier
monitoring.
- Fixed
an issue where an idle SSH session to iLO3 from a PUTTY client may freeze
or may get disconnected with an error message “Incoming packet was garbled
on decryption”.
- SSH
connection to iLO from an OpenSSH 5.9 client will now work even when a
reduced list of key-exchange algorithm is not indicated.
Other issues fixed in iLO 1.55.02
(BL8x0c i2 26.36):
- IPMI
chassis status now properly reflects the sensor status when cover is off
or after a fan failure
- MP-iLO’s
15 minute auto-logoff no longer truncates a V-media created ISO Image
Fixes in SFW 1.95 (BL8x0c i2 26.36):
- Fixed
a very rare issue where a system running HP-UX might appear hung for 12
seconds or a clustered system might crash or reset if the heartbeat timer
was set to a value lower than 12 seconds.
- Fixed
an issue where a failed CPU socket would not get de-configured, causing
the system to hang and not boot to EFI shell, or to continuously reboot,
with the error "BOOT_CPU_LATE_SELF_TEST_FAIL".
Boot Code 6.2.25 (from 6.2.21) for embedded LOM, NC532m:
- In
some cases, only 2 PCI functions are exposed in multi-function mode.
LPe1205 HBA FW version 2.02x2 (from
2.00a4):
- I/O
“illegal frames received” errors may be reported intermittently by
FC disks linked through an 8Gb Hp/Emulex FC card if a disk reset is
performed
during heavy I/O load.
Bundle Version: 7.1.1.3:
ENHANCEMENTS / FIXES:
HP Integrity BL860c/BL870c/BL890c i4
Server System / iLo firmware:
Support added to CloudSystem Matrix (CSM) 7.1.1 environment
Virtual Connect:
Please refer to the VC 3.70 Release notes for fixes and enhancements.
Onboard Administrator:
Please refer to the OA 3.60 Release notes for fixes and enhancements.
For more information on HP CloudSystem Matrix
7.1.1.3 fixes, updates and enhancements, please refer to the CloudSystem Matrix Release notes & Compatibility
Chart
Bundle Version 7.1.1(a):
Server FW: 26.34
SFW / ILO:
- Fixed
an issue where a memory update operation may not complete properly when an
L2 cache line encounters a second single bit data error. This may result
in the possibility of undefined system behavior. See Intel Specification
Update for
more information. If Specification
Update link
does not work, HP recommend to go to www.intel.com and search for the latest version
of the Intel® Itanium® Processor 9300 Specification Update.
- Fixed
an issue where PAL returned no information on bus log overflow
- Fixed
an issue where an invalid log format may have been generated by hardware
when multiple MLD errors occur in a small window
Virtual Connect:
Please refer to the VC 3.70 Release notes for fixes and enhancements.
Onboard Administrator:
Please refer to the OA 3.60 Release notes for fixes and enhancements.
Bundle Version 7.1.1:
Server FW: 26.33
Virtual Connect:
Please refer to the VC 3.70 Release notes for fixes and enhancements.
Onboard Administrator:
Please refer to the OA 3.60 Release notes for fixes and enhancements.
Bundle Version 7.1(a) / 7.0(a):
Virtual Connect:
Please refer to the VC 3.60 Release notes for fixes and enhancements.
Onboard Administrator:
Please refer to the OA 3.56 Release notes for fixes and enhancements.
Server FW: 26.33:
System / iLo firmware (1.53.02):
Enhancements:
- The serial
port can now be set permanently to AUX mode using a new option provided in
iLO. AUX mode will be retained even after an AC power cycle.
Fixes:
- The
system iLO may hang if it remains up without being reset for days or
weeks, and a system power cycle may be required to recover
- If
one of the following systems is updated with Firmware bundle 26.31 (iLO
MFW version 01.51.03), the product number will be reset to the factory
default, which may cause warranty entitlement issues when calling HP for
support:* HP BL860c/BL870c/BL890c i2 systems with a hardware
upgrade kit installed (product number AM358A, AM364A, AM365A, AM359A, and
AM366A)* HP BL860c/BL870c/BL890c i2 systems sold as HP Remarketed
(product numbers ending in “R”, AD399AR, AH383AR, AM329AR, AH384AR, and