TITLE: HPE Integrity Superdome X Server Firmware Bundle

VERSION:
Bundle Version: 8.7.84

DESCRIPTION:                                                                                                                                                         
This bundle contains the Complex and nPartition Firmware updates for HPE Integrity Superdome X Servers with BL920s Gen8 and Gen9 blades. It includes an integrated OA (Onboard Administrator).

WARNING: If you are updating from a version prior to 6.0.42, you must install 6.0.42 (bridge release for digital signing) prior to updating to this version.

 

WARNING: To ensure that the OA GUI continues to work after December 31, 2016, after upgrading from version 7.6.0 or earlier to version 8.2.106 or later, the OA SHA1 self-signed certificate will be removed and replaced with SHA256 self-signed certificate. To prevent security warnings, customer is encouraged to re-generate the self-signed certificate with the common name (CN) matching exactly the OA hostname as known by the web browser. See the Certificate Administration section in the OA user guide for more information. 

Note:                                                                                                                                                                  

 

Complex Firmware

 

5.73.0 1

6.0.42

7.5.0

7.6.0

8.2.106

8.4.84

8.5.3

8.7.84

Partition Firmware

5.73.0

Yes

Yes

Yes 1,3

Yes1,3

Yes1,3

Yes1,3

Yes1,3

Yes1,3

6.0.42

No

Yes

Yes 2,3

Yes2,3

Yes2,3

Yes2,3

Yes2,3

Yes2,3

7.5.0

No

No

Yes

Yes

Yes

Yes

Yes

Yes

7.6.0

No

No

No

Yes

Yes

Yes

Yes

Yes

8.2.106

No

No

No

No

Yes

Yes

Yes

Yes

8.4.84

No

No

No

No

No

Yes

Yes

Yes

8.5.3

No

No

No

No

No

No

Yes

Yes

8.7.84

No

No

No

No

No

No

No

Yes


Note 1:
 Updating Complex FW from 5.X.X to 7.5.0 or later requires installing 6.0.42 first because of changes to the digital firmware bundle signature.
Note 2: Online Complex FW updates from 6.0.42 to 7.5.0 or later will show Mixed firmware due to newer PDH FPGA in 7.5.0.  Partition operation is supported in this condition. To complete the PDH FPGA update, turn off the partition(s) when convenient, and rerun firmware update.
Note 3: BL920s Gen8 Blades support running Complex FW version 7.5.0 or later with Partition FW 5.73.0 or 6.0.42, but Gen9 Blades require both Complex and nPartition FW version 7.5.0 or later when using v3 family processors, or version 8.2.106 or later when using v4 family processors.

UPDATE RECOMMENDATION: Recommended
HPE recommends systems used in Mission Critical environments update to this revision of firmware during the next system maintenance period in order to improve system reliability.
Note: Review the FIXES section to check if your system may be affected by the issue fixed in this release.        

 [ ] Critical                                                                          

    [ ] Panic, [ ] Hang, [ ] Abort, [ ] Corruption, [ ] Memory Leak, [ ] Performance

    [ ] Security

    [ ] Hardware Enablement, [ ] Software Enablement

[ ] Required

[X] Recommended

[ ] Optional

    [ ] Hardware Enablement, [ ] Software Enablement, [ ] non-critical

[ ] Initial Customer Release

 

SUPERSEDES:
Bundle version: 8.5.3

PRODUCT MODEL(S):          
HPE Integrity Superdome X Servers

OPERATING SYSTEMS:  
OSes supported on Gen9 blades with v4 family processors:

RHEL 6.7, 6.8, 6.9, 7.2, 7.3

·         SLES 11 SP4, 12 SP1, 12 SP2

·         Windows Server 2012 R2, 2016

·         VMware vSphere 6.0 U2, 6.0 U3, 6.5

OSes supported on Gen9 blades with v3 family processors:

·         RHEL 6.6, 6.7, 6.8, 6.9, 7.1, 7.2, 7.3

·         SLES 11 SP3, 11 SP3 for SAP, 11 SP4, 12, 12 SP1, 12 SP2

·         Windows Server 2012 R2, 2016

·         VMware vSphere 5.5 U3, 6.0 U1, 6.0 U2, 6.0 U3

OSes supported on Gen8 blades:

·         RHEL 6.5, 6.6, 6.7, 6.8, 6.9, 7.0, 7.1, 7.2, 7.3

·         SLES 11 SP3, 11 SP3 for SAP, 11 SP4, 12, 12 SP1, 12 SP2

·         Windows Server 2012 R2, 2016

·         VMware vSphere 5.5 U2, 5.5 U3, 6.0, 6.0 U1, 6.0 U2, 6.0 U3

 

LANGUAGES:
International English


FIXES:
nPartition firmware fix:

·         Blades with a mix of 32GB and 64GB DDR4 PC-2133 and PC-2400 DIMMs would be indicted and marked as degraded even though the blade and all its installed memory was available to the partition. With this release the blade is no longer indicted and marked as degraded.

IMPORTANT: Due to a compatibility issue, blades with a mix of 32GB DDR4 PC-2133 and PC-2400 DIMMs will fail to power on if these DIMMs are installed within the same DRAM bus or lockstep pairs. For more details, see advisory c05404697

ENHANCEMENTS:

·         Added support for RHEL 6.9, VMware 6.0 U3 and 6.5

·         Added support for Xeon E7-8894

·         Added support for iSCSI on the 650FLB adapters (FW version 11.1.183.23) with Windows 2016, VMware 6.5 and RHEL 7.3 starting with Superdome X firmware version 8.7.84 (bundle 2017.03)

COMPATIBILITY/INTEROPERABILITY:
Note: See the
Firmware Matrix for HPE Integrity Superdome X servers for latest information at
http://h20566.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=7161269&docId=emr_na-c04739260

The following IO cards and versions are supported with Superdome X firmware version 8.7.84:

IO card

Gen8 Blades

Gen9 Blades (v3)

Gen9 Blades (v4)

Supported OSes

HPE Ethernet 10Gb 2-port 560FLB and  560M Adapter

UEFI: 5.0.20 

UEFI: 5.0.20 

UEFI: 5.0.20

Linux, Windows, VMware3

HPE QMH2672 16GB Fibre Channel Host Bus Adapter

Multiboot 6.01.14
UEFI 6.39
FW: 8.02.51

Multiboot 6.01.14
UEFI 6.39
FW: 8.02.51

Multiboot 6.01.14
UEFI 6.39
FW: 8.02.51

Linux, Windows, VMware3

HPE FlexFabric 10 Gb 2-port 534M and 534FLB Adapter 1,2

UEFI 7.14.65
Boot code: 7.13.75
PXE/MBA: 7.14.5

Not Supported

Not Supported

Linux, VMware

HPE FlexFabric 20 Gb 2-port 630M and 630FLB card 1,2

Not Supported

UEFI 7.14.65
Boot code: 7.13.75
PXE/MBA: 7.14.5

Not Supported

Linux, Windows, VMware

HPE FlexFabric 20Gb 2-port 650M and 650FLB Adapter 2,4

Not Supported

Not Supported

FW: 11.1.183.23

Linux, Windows, VMware3

HPE Infiniband FDR 2-Port 545M Adapter

Not Supported

FW 10.16.1038
UEFI 14.10.17

FW 10.16.1038
UEFI 14.10.17

Linux only

 

NOTE 1: The HPE FlexFabric 2-port 10GB 534M/534FLB and 20GB 630M/630FLB Adapters (Mezzanine and LOM) only provide Ethernet network support.
NOTE 2
: FCoE is currently not supported with the I/O Adapters for HPE Integrity Superdome X with BL920s Gen8 and Gen9 server blades.
iSCSI is supported starting with Superdome X firmware version 8.7.84 (bundle 2017.03) on RHEL 7.3, Windows 2016 and VMware 6.5 with the 650FLB adapter.

NOTE 3: Minimum firmware version on Gen9 Blades with v4 family processors is 8.2.106 with Linux, 8.4.84 with Windows Server 2012/VMware and 8.5.3 with Windows Server 2016.
NOTE 4:
RoCE is supported on the 650M/FLB adapters with Linux RHEL 7.2 or later (with IO version 10.7.110.34 or later) and with Windows Server 2016 (with IO version 11.1.183.23 or later).

      Recommended I/O firmware:

         HPE recommends running with the IO firmware versions displayed in the table above. They can be found in the HPE Integrity Superdome X IO Firmware and Windows Drivers image (version 2016.11), available on the Superdome X firmware download page on HPE Support Center. Select your OS and go under the Software CD-ROM section. 

o   Warning: Do not update I/O using the SPP (Service Pack for Proliant) as it may install versions that are not supported, which may cause unnecessary downtime.

Note:      

 

      Required I/O drivers:

 

A.      Linux 

All Linux OS related information is available from the Linux white paper Running Linux on HPE Integrity Superdome X:

                                                              i.      Check the HPE Servers Support & Certification Matrices for special OS requirements for the HPE Integrity Superdome X Server

                                                             ii.      Linux SMH and WBEM providers: HPE recommends that you install the latest versions of the SMH and WBEM providers for your SLES or RHEL Operating System from the Software Delivery Repository (SDR). Superdome X providers are available under http://downloads.linux.hpe.com/repo/bl920-wbem/
Note: You must install the SMH package prior to the WBEM providers or in the same session.

Note: Reboot is not required for the SMH and WBEM provider changes to take effect.

 

                                                          iii.      Check the Linux white paper for additional details and recommendations.

 

B.      Windows
I/O drivers and WBEM providers for Windows 2012 R2 or 2016 for Superdome X are available as part of the HPE Integrity Superdome X IO Firmware and Windows Drivers image version 2016.11 on the Superdome X download page on HPE Support Center, under Software CD-ROM. Follow the instructions in the bundle to install the components.

For more information on installing Windows OS and components on Superdome X, see the Windows white paper Running Microsoft Windows Server on HPE Integrity Superdome X, at http://www.hpe.com/support/superdomeXwindows-whitepaper.

C.      VMware:

I/O drivers and WBEM providers for VMware are available from this link (apr2017 required for VMware 6.5 support): http://vibsdepot.hpe.com/sdx/downloads/

o   For Gen8 blades and Gen9 blades with Intel v3 family processors, select: gen8gen9v3

o   For Gen9 blades with Intel v4 family processors, select: gen9v4

For more information on installing VMware OS and components on Superdome X, see the VMware white paper Running VMware vSphere on HPE Integrity Superdome X available at http://www.hpe.com/support/superdomeXvmware-whitepaper

 

PREREQUISITES:
NOTE:

WARNING:

 

IMPORTANT:

1.       Isolate the management network by keeping it separate from the production network and not putting it on the open internet without additional access authentication.

2.       Patch and Maintain LDAP and web servers.

3.       Run the up-to-date viruses and malware scanners in your network environment

4.       Apply HPE Firmware updates as recommended.

 

INSTALLATION INSTRUCTIONS:

Please review all instructions and the "Hewlett Packard Enterprise Support Tool License Terms" or your Hewlett Packard Enterprise support terms and conditions for precautions, scope of license, restrictions, and limitation of liability and warranties, before installing this package. It is important that you read and understand these instructions completely before you begin. This can determine your success in completing the firmware update.

These instructions describe how to install the firmware version 8.7.84. The list below is a summary of the steps to install the firmware.

A.       Downloading the bundle

B.       Updating Complex firmware using OA CLI  

C.     Updating specific nPartition firmware using OA CLI (optional)

D.       Updating IO firmware, SMH and WBEM providers


NOTE:
For more details, review the HP Integrity Superdome X and Superdome 2 Onboard Administrator Command Line Interface User Guide. 

Update Superdome X Complex from Firmware Bundle using Onboard Administrator's Command Line Interface (CLI)

A. Downloading the bundle

1.       Download the file hpsdx-8.7.84-fw.bundle in a new folder in your desktop.

2.       Copy the bundle file to a USB Key or to a FTP Server reachable from Onboard Administrator.

NOTE: If you are using FTP, then please make sure the transfer mode is set to "Binary".

NOTE: At this time, the OA only supports 16GB or less USB keys.

Note:

B. Updating Superdome X Complex and nPartition firmware using OA CLI

1.       Connect to Onboard Administrator over Telnet or SSH and login to get the command line prompt.

NOTE: Only in case of offline firmware update, do the following steps a. and b. below, otherwise skip to step 2 for online firmware update. Offline update requires downtime for the entire server. Online update is recommended for servers with firmware versions 5.73.0 or later (skip a. and b. and go directly to step 2 for online update).

Offline update:

a. Gracefully shutdown OS in each partition, using shutdown -h, as forcing partition power off is likely to corrupt OS.

b. Power down all blades using the following command (not required if performing an online firmware update):
     OA1-CLI> POWEROFF PARTITION X FORCE
This may take some time. You can use the following command to confirm status of partitions:
      OA1-CLI> parstatus P


NOTE: The update procedure for online update of complex firmware on systems with firmware version 5.73.0 or later starts here.

2. Verify communications between the OA and all installed Blades, using the connect blade command for each of the installed Cell Blades.
NOTE:  If the OA to any blade communications is not working, update firmware will fail.

                      sd-oa1> connect blade 1

                      Connecting to bay 1 ...

 User:OAtmp-Administrator-53A9 logged-in to ILO-B.hp.com(16.11.18.7 / FE80)
 iLO 4 Advanced for BladeSystem HP limited-distribution date-restricted test 1.57 at Apr 29 2014
Server Name: sd-oa1
Server Power: On 

3. Use the update firmware command, as shown below, to point to Integrated Firmware Update Bundle at a valid ftp location.

OA1-CLI> UPDATE FIRMWARE <uri> all

NOTE: The "all" option must be used in order to update complex AND partition firmware

             Where The <uri> should be formatted as usb://<path> for USB installations. Use the SHOW
             USBKEY command to obtain the <path>.

Example:

Using FTP:

update firmware ftp://user:passwd@15.1.1.75/firmware/hpsdx-8.7.84-fw.bundle all

Using USB Key:

update firmware usb://d2/ hpsdx-8.7.84-fw.bundle all

NOTE: The Firmware update process can take up to 1 hour to complete. During this process you might notice no progress for up to 30 minutes at certain time. In between the updates, connection to OA will be lost as OA will reboot to proceed towards other firmware updates. OA might take up to 30 minutes to come to ready state after the reboot. After OA is rebooted you can reconnect back to OA and login to confirm successful update.

4.       Run the OA command UPDATE SHOW FIRMWARE to display the versions of complex bundle last installed and firmware versions installed.

Example:

OA1-CLI> UPDATE SHOW FIRMWARE

Configured complex firmware bundle version: 8.7.84

====================================================================

Firmware on all devices matches the complex configured bundle version
Note: Partition firmware activation requires a partition reboot (see step C. 5.).

5.       Verify all partitions are ready to be started using:

parstatus -P command (this command will not work until the OA restart is complete)

NOTE: Step 6 is only needed in case of offline firmware update (steps 1. a. and b. above)

6. Power on the partitions using poweron partition [X] for each of the nPartitions.

C. Updating specific nPartition firmware using OA CLI (optional)

    Note: Step C is not needed if you have updated both complex and all partition firmware in step B above. 

1.       Connect to Onboard Administrator over Telnet or SSH and login to get the command line prompt.

2.       Run the OA command UPDATE SHOW NPARTITION ALL to display the versions of partition firmware installed.

Example:

OA1-CLI> UPDATE SHOW NPARTITION ALL

nPartition firmware version applied to partition 1 nPar0001

Configured nPartition Firmware Version: 8.7.84

Active nPartition Firmware Version: 8.7.84

nPartition firmware on all blades matches the partition's configured version

 

3.       Use the update npartition command, as shown below, to point to Integrated Firmware Update Bundle at a valid ftp location and update the desired partition, taking into account planned downtime for OS update and reboot.

OA1-CLI> UPDATE NPARTITION <npar name or number or ALL> <uri>

Where <npar name or number> is the partition whose nPartition firmware should be updated.
The ALL keyword would update nPartition firmware for all blades in the enclosure.

The <uri> should be formatted as usb://<path> for USB installations. Use the SHOW USBKEY command to obtain the <path>.

Examples:

Using FTP:

update npartition 1 ftp://user:passwd@15.1.1.75/firmware/hpsdx-8.7.84 -fw.bundle

Using USB Key:

update npartition 1 usb://d2/hpsdx-8.7.84-fw.bundle

4.       Repeat step 2 to verify that the requested update was successful

5.       Restart nPar to activate partition firmware (when ready for Partition downtime)

Note: if nPartition firmware was updated in step B, but not activated, shut down all running OSs in the nPar then power off the nPar, then power on the nPar. The nPar restart will cause the updated nPartition firmware to be activated. The following sequence can be used:

OA1-CLI>POWEROFF PARTITION< npar#> OVERRIDE

OA1-CLI> POWEROFF PARTITION< npar#> FORCE

OA1-CLI> POWERON PARTITION <npar#>

       Run the OA command UPDATE SHOW NPARTITION ALL to display the versions of partition firmware installed.

Example:

OA1-CLI> UPDATE SHOW NPARTITION ALL

D. Updating IO firmware, SMH and WBEM providers

See the section COMPATIBILITY/INTEROPERABILITY section for supported IO cards, WBEM providers, and supported versions.

DETERMINING CURRENT VERSION:

KNOWN ISSUES & WORKAROUNDS:

·         Updating the Superdome X firmware via FTP may fail if the password contains some special characters, for instance, §, $, & or space (but not !). This is due to interpreting the special character as part of the command instead of the password.
Workaround: Use quotes around the URI (ex. update firmware ‘ftp://user:passwd@15.1.1.75/firmware/hpsdx-8.7.84 -fw.bundle’ all).

·         In very rare cases, after booting a Brocade 16Gb/28 SAN Switch, all internal ports of the switch attached to a 16Gb Fibre Channel QH2672 mezzanine card on a Superdome X server may be running at 8 Gbps instead of the configured 16 Gbps. This is due to the OA not detecting the server backplane type on time and may cause a SAN performance degradation. For more details, see advisory c05384312.

·         With RHEL 7.3, the time for booting to the OS prompt increases with the number of iSCSI ports and LUNs configured. It may take up to 2 hours with 32 iSCSI ports assigned to iSCSI LUNs, due to the system taking a lot of time scanning for all the ports and their mapped disks.

Workaround: Remove or de-configure all java environments other than the Oracle version as this is the only JVM currently supported by iLO. The Oracle Java 7 JRE works correctly.


DISCLAIMER:

The information in this document is subject to change without notice.

Hewlett Packard Enterprise makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.

This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be reproduced, photocopied, or translated to another language without the prior written consent of Hewlett Packard Enterprise.

(C) Copyright 2015-2017 Hewlett Packard Enterprise Development L.P.

FEEDBACK
As we are continuing to improve the firmware management process we welcome your feedback on this document and on the firmware update process: TEAM-FWupdateFeedback@groups.ext.hpe.com  

SUPERSEDES HISTORY:
Version 8.5.3:
FIXES:

nPartition firmware fix:

Complex firmware fixes:

 

ENHANCEMENTS:

 

Version 8.4.84:

FIXES:
nPartition firmware fix:

Complex firmware fixes:

 

ENHANCEMENTS:

 

Version 8.2.106:

nPartition firmware fixes:


ENHANCEMENTS:

·         Added support for Intel EX v4 family processors on BL920s Gen9 blades with firmware 8.2.106

 

Version 7.6.0:

nPartition firmware:

ENHANCEMENTS:

February 2016 updates:

January 2016 updates:

 

Version 7.5.0:

ENHANCEMENTS:

 

FIXES:

 

Version 6.0.42:
ENHANCEMENTS:

Bundle version 6.0.42(a):

Bundle version 6.0.42:

 

FIXES:


Version 5.73.0:
ENHANCEMENTS:

Changes included in bundle version 5.73.0(b):

 

Changes included in bundle version 5.73.0(a):

 

Changes included in bundle version 5.73.0:

FIXES:
Fixes included in bundle version 5.73.0(a), 5.73.0(b):

Fixes included in bundle version 5.73.0: