TITLE: HPE Integrity Superdome X Server Firmware Bundle
VERSION:
Bundle Version: 8.2.106
DESCRIPTION:
This bundle contains the Complex and nPartition
Firmware updates for HPE Integrity Superdome X Servers with BL920s Gen8 and
Gen9 blades. It
includes an integrated OA (Onboard Administrator).
WARNING: If you are updating from a version prior to 6.0.42, you must install 6.0.42 (bridge release for digital signing) prior to updating to version 7.5.0 or later.
WARNING: To ensure that the OA GUI continues to work after December 31, 2016, after upgrading to version 8.2.106, the OA SHA1 self-signed certificate will be removed and replaced with SHA256 self-signed certificate. To prevent security warnings, customer is encouraged to re-generate the self-signed certificate with the common name (CN) matching exactly the OA hostname as known by the web browser. See the Certificate Administration section in the OA user guide for more information.
Note:
Complex Firmware |
||||||
|
5.73.0 1 |
6.0.42 |
7.5.0 |
7.6.0 |
8.2.106 |
|
Partition Firmware |
5.73.0 |
Yes |
Yes |
Yes 1,3 |
Yes1,3 |
Yes1,3 |
6.0.42 |
No |
Yes |
Yes 2,3 |
Yes2,3 |
Yes2,3 |
|
7.5.0 |
No |
No |
Yes |
Yes |
Yes |
|
7.6.0 |
No |
No |
No |
Yes |
Yes |
|
8.2.106 |
No |
No |
No |
No |
Yes |
Note 1: Updating Complex FW from 5.X.X to 7.5.0 or later requires installing
6.0.42 first because of changes to the digital firmware bundle signature.
Note 2: Online Complex FW updates from 6.0.42 to 7.5.0 or later will
show “Mixed” firmware due to newer PDH FPGA in 7.5.0. Partition operation
is supported in this condition. To complete the PDH FPGA update, turn off the
partition(s) when convenient, and rerun firmware update.
Note 3: BL920s Gen8 Blades support running Complex FW version 7.5.0 or
later with Partition FW 5.73.0 or 6.0.42, but Gen9 Blades require both Complex
and nPartition FW version 7.5.0 or later when
using v3 family processors, or version 8.2.106 or later when using v4
family processors.
UPDATE RECOMMENDATION:
Recommended
HPE recommends systems used in Mission Critical environments update to this
revision of firmware during the next system maintenance period in order to
improve system reliability.
Note: Review the FIXES section to check if your system might be affected by
the issue fixed in this release.
[ ] Critical
[ ] Panic, [ ] Hang, [ ] Abort, [ ] Corruption, [ ] Memory Leak, [ ] Performance
[ ] Security
[ ] Hardware Enablement, [ ] Software Enablement
[ ] Required
[X] Recommended
[ ] Optional
[X] Hardware Enablement, [ ] Software Enablement, [ ] non-critical
[ ] Initial Customer Release
SUPERSEDES:
Bundle version: 7.6.0
PRODUCT MODEL(S):
HPE Integrity Superdome X Servers
OPERATING SYSTEMS:
Supported OS’es on Gen8 blades only:
Supported OS’es on Gen8 and Gen9 v3 blades only:
Supported OS’es on all blades:
LANGUAGES:
International English
FIXES:
nPartition firmware fixes:
ENHANCEMENTS:
COMPATIBILITY/INTEROPERABILITY:
Note: See the Firmware
Matrix for HPE Integrity Superdome X servers for latest information at
http://h20566.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=7161269&docId=emr_na-c04739260
The following IO cards and versions are supported with Superdome X firmware version 8.2.106:
IO card |
Gen8 Blades |
Gen9 v3 Blades |
Gen9 v4 Blades |
Supported OS’es |
HP Ethernet 10Gb 2-port 560FLB and 560M Adapter |
UEFI: 4.9.10 |
UEFI: 4.9.10 |
UEFI: 4.9.10 |
Linux, Windows, VMware3 |
HP QMH2672 16GB Fibre Channel Host Bus Adapter |
UEFI 6.37 |
UEFI 6.37 |
UEFI 6.37 |
Linux, Windows, VMware3 |
HP FlexFabric 10 Gb 2-port 534M and 534FLB Adapter 1,2 |
UEFI 7.12.31 |
Not Supported |
Not Supported |
Linux, VMware |
HP FlexFabric 20 Gb 2-port 630M and 630FLB card 1,2 |
Not Supported |
UEFI 7.12.31 |
Not Supported |
Linux, Windows, VMware |
HP FlexFabric 20Gb 2-port 650M and 650FLB Adapter |
Not Supported |
Not Supported |
FW: 10.7.110.34 |
Linux only |
HP Infiniband FDR 2-Port 545M Adapter |
Not Supported |
FW 10.10.50.52 |
Not Supported |
Linux only |
NOTE 1: The HP FlexFabric
2-port 10GB 534M/534FLB and 20GB 630M/630FLB Adapters (Mezzanine and LOM) only provide
Ethernet network support.
NOTE 2: FCoE is currently not supported with the
I/O Adapters for HPE Integrity Superdome X with BL920s Gen8 and Gen9 server
blades.
Note 3: Gen9-v4 Blades support Linux only and require firmware version 8.2.106 or later.
Recommended I/O firmware:
· It is recommended to update to the IO firmware versions
displayed in the table above. They can be found in the “HPE Integrity Superdome
X IO Firmware and Windows Drivers image” (version 2016.03), available on the
Superdome X firmware download page on HPE Support Center.
Select your OS and go under the “Software – CD-ROM” section.
Note: IO Firmware for the HPE FlexFabric 20Gb 2-port 650M/650FLB Adapter is not included in the above
image. It is available in the 650M/650FLB adapter firmware bundle version 2016.02.02 (firmware for CNA (XE100 Series)).
Note:
Required I/O drivers:
A. Linux
All Linux OS related information is available from the Linux white paper “Running Linux on HPE Integrity Superdome X”:
i. Check the HPE Servers Support & Certification Matrices for special OS requirements for the HPE Integrity Superdome X Server
ii. Linux SMH and WBEM
providers: HPE recommends that you
install the latest versions of the SMH and WBEM providers for your SLES or RHEL
Operating System from the Software Delivery Repository (SDR). Superdome X
providers are available under http://downloads.linux.hpe.com/repo/bl920-wbem/
Note: You must install the SMH package prior to the WBEM providers or in
the same session.
Note: Reboot is not required for the SMH and WBEM provider changes to take effect.
iii. Check the Linux white paper for additional details and recommendations.
B.
Windows
(not supported with Gen9 v4 blades)
I/O drivers and WBEM providers for Windows 2012 R2 for Superdome
X are available as part of the “HPE Integrity Superdome X IO Firmware and
Windows Drivers image” version 2016.03 on the Superdome X download
page on HPE Support Center, under
“Software – CD-ROM”. Follow
the instructions in the bundle to install the components.
For more information on installing Windows OS and components on Superdome X, see the Windows white paper “Running Microsoft Windows Server on HPE Integrity Superdome X”, at http://www.hpe.com/support/superdomeXwindows-whitepaper.
C. VMware (not supported
with Gen9 v4 blades)
I/O drivers and WBEM
providers for VMware are available from this link: http://vibsdepot.hpe.com/sdx/downloads/feb2016.
For more information
on installing VMware OS and components on Superdome X, see the VMware white
paper “Running VMware vSphere on HPE Integrity Superdome X” available at https://www.hpe.com/h20195/v2/GetDocument.aspx?docname=4AA6-5018ENW&doctype=Technical
white paper
PREREQUISITES:
NOTE:
WARNING:
IMPORTANT:
1. Isolate the management network by keeping it separate from the production network and not putting it on the open internet without additional access authentication.
2. Patch and Maintain LDAP and web servers.
3. Run the up-to-date viruses and malware scanners in your network environment
4. Apply HPE Firmware updates as recommended.
INSTALLATION INSTRUCTIONS:
Please review all instructions and the "Hewlett Packard Enterprise Support Tool License Terms" or your Hewlett Packard Enterprise support terms and conditions for precautions, scope of license, restrictions, and limitation of liability and warranties, before installing this package. It is important that you read and understand these instructions completely before you begin. This can determine your success in completing the firmware update.
These instructions describe how to install the firmware version 8.2.106. The list below is a summary of the steps to install the firmware.
A. Downloading the bundle
B. Updating Complex firmware using OA CLI
C. Updating specific nPartition firmware using OA CLI (optional)
D. Updating IO firmware, SMH and WBEM providers
NOTE: For more details, review the “HP Integrity Superdome X and
Superdome 2 Onboard Administrator Command Line Interface User Guide”.
Update Superdome X Complex from Firmware Bundle using Onboard Administrator's Command Line Interface (CLI)
A. Downloading the bundle
1. Download the file hpsdx-8.2.106-fw.bundle in a new folder in your desktop.
2. Copy the bundle file to a USB Key or to a FTP Server reachable from Onboard Administrator.
NOTE: If you are using FTP, then please make sure the transfer mode is set to "Binary".
NOTE: At this time, the OA only supports 16GB or less USB keys.
Note:
B. Updating Superdome X Complex and nPartition firmware using OA CLI
1. Connect to Onboard Administrator over Telnet or SSH and login to get the command line prompt.
NOTE: Only in case of offline firmware update, do the following steps a. and b. below, otherwise skip to step 2 for online firmware update. Offline update requires downtime for the entire server. Online update is recommended for servers with firmware versions 5.73.0 or later (skip a. and b. and go directly to step 2 for online update).
Offline update:
a. Gracefully shutdown OS in each
partition, using shutdown -h, as forcing partition power off is likely to
corrupt OS.
b. Power down all blades using the following command (not required if
performing an online firmware update):
OA1-CLI> POWEROFF PARTITION X FORCE
This may take some time. You can use the following
command to confirm status of partitions:
OA1-CLI> parstatus
–P
NOTE: The update procedure for online update of complex firmware on systems
with firmware version 5.73.0 or later starts here.
2. Verify
communications between the OA and all installed Blades, using the connect
blade command for each of the installed Cell Blades.
NOTE: If the OA to any blade communications is not working,
update firmware will fail.
sd-oa1> connect blade 1
Connecting to bay 1 ...
User:OAtmp-Administrator-53A9
logged-in to ILO-B.hp.com(16.11.18.7 / FE80)
iLO 4 Advanced for BladeSystem HP
limited-distribution date-restricted test 1.57 at Apr 29 2014
Server Name: sd-oa1
Server Power: On
3. Use the update firmware command, as shown below, to point to Integrated Firmware Update Bundle at a valid ftp location.
OA1-CLI> UPDATE FIRMWARE <uri> all
NOTE: The "all" option must be used in order to update complex AND partition firmware
Where The <uri> should be formatted as usb://<path> for USB installations. Use
the SHOW
USBKEY
command to obtain the <path>.
Example:
Using FTP:
update firmware ftp://user:passwd@15.1.1.75/firmware/hpsdx-8.2.106-fw.bundle all
Using USB Key:
update firmware usb://d2/ hpsdx-8.2.106-fw.bundle all
NOTE: The Firmware update process can take up to 1 hour to complete. During this process you might notice no progress for up to 30 minutes at certain time. In between the updates, connection to OA will be lost as OA will reboot to proceed towards other firmware updates. OA might take up to 30 minutes to come to ready state after the reboot. After OA is rebooted you can reconnect back to OA and login to confirm successful update.
4. Run the OA command UPDATE SHOW FIRMWARE to display the versions of complex bundle last installed and firmware versions installed.
Example:
OA1-CLI> UPDATE SHOW FIRMWARE
Configured complex firmware bundle version: 8.2.106
====================================================================
Firmware
on all devices matches the complex configured bundle version
Note: Partition firmware activation requires a partition reboot
(see step C. 5.).
5. Verify all partitions are ready to be started using:
parstatus -P command (this command will not work until the OA restart is complete)
NOTE: Step 6 is only needed in case of offline firmware update (steps 1. a. and b. above)
6. Power on the partitions using poweron partition [X] for each of the nPartitions.
C. Updating specific nPartition firmware using OA CLI (optional)
Note: Step C is not needed if you have updated both complex and all partition firmware in step B above.
1. Connect to Onboard Administrator over Telnet or SSH and login to get the command line prompt.
2. Run the OA command UPDATE SHOW NPARTITION ALL to display the versions of partition firmware installed.
Example:
OA1-CLI> UPDATE SHOW NPARTITION ALL
nPartition firmware version applied to partition 1 nPar0001
Configured nPartition Firmware Version: 8.2.106
Active nPartition Firmware Version: 8.2.106
nPartition firmware on all blades matches the partition's configured version
3. Use the update npartition command, as shown below, to point to Integrated Firmware Update Bundle at a valid ftp location and update the desired partition, taking into account planned downtime for OS update and reboot.
OA1-CLI> UPDATE NPARTITION <npar name or number or ALL> <uri>
Where <npar name or number> is the partition whose nPartition firmware should be updated.
The ALL keyword would update nPartition firmware for
all blades in the enclosure.
The <uri> should be formatted as usb://<path> for USB installations. Use the SHOW USBKEY command to obtain the <path>.
Examples:
Using FTP:
update npartition 1 ftp://user:passwd@15.1.1.75/firmware/hpsdx-8.2.106-fw.bundle
Using USB Key:
update npartition 1 usb://d2/hpsdx-8.2.106-fw.bundle
4. Repeat step 2 to verify that the requested update was successful
5. Restart nPar to activate partition firmware (when ready for Partition downtime)
Note: if nPartition firmware was updated in step B, but not activated, shut down all running OSs in the nPar then power off the nPar, then power on the nPar. The nPar restart will cause the updated nPartition firmware to be activated. The following sequence can be used:
OA1-CLI>POWEROFF PARTITION< npar#> OVERRIDE
OA1-CLI> POWEROFF PARTITION< npar#> FORCE
OA1-CLI> POWERON PARTITION <npar#>
Run the OA command UPDATE SHOW NPARTITION ALL to display the versions of partition firmware installed.
Example:
OA1-CLI> UPDATE SHOW NPARTITION ALL
D. Updating IO firmware, SMH and WBEM providers
See the section COMPATIBILITY/INTEROPERABILITY section for supported IO cards, WBEM providers, and supported versions.
DETERMINING CURRENT VERSION:
KNOWN ISSUES & WORKAROUNDS:
DISCLAIMER:
The information in this document is subject to change without notice.
Hewlett Packard Enterprise makes no warranty of any kind with regard to this
material, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose. Hewlett-Packard shall not
be liable for errors contained herein or for incidental or consequential
damages in connection with the furnishing, performance, or use of this
material.
This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be reproduced, photocopied, or translated to another language without the prior written consent of Hewlett Packard Enterprise.
(C) Copyright 2015-2016 Hewlett Packard Enterprise Development L.P.
SUPERSEDES
HISTORY:
Version 7.6.0:
nPartition firmware:
ENHANCEMENTS:
February 2016 updates:
January 2016 updates:
Version 7.5.0:
ENHANCEMENTS:
FIXES:
The OA GUI now properly detects and displays a valid firmware bundle present on a USB stick in the external USB drive.
Version 6.0.42:
ENHANCEMENTS:
Bundle version 6.0.42(a):
Bundle version 6.0.42:
FIXES:
Version 5.73.0:
ENHANCEMENTS:
Changes included in bundle version 5.73.0(b):
Changes included in bundle version 5.73.0(a):
Changes included in bundle version 5.73.0:
FIXES:
Fixes included in bundle version 5.73.0(a), 5.73.0(b):
Fixes included in bundle version 5.73.0:
FEEDBACK
As we are continuing to improve the firmware management
process we welcome your feedback on this document and on the firmware update
process: TEAM-FWupdateFeedback@groups.ext.hpe.com