TITLE: HP Integrity Superdome X Server Firmware Bundle

VERSION:
Bundle Version: 7.5.0

DESCRIPTION:
This bundle contains the Complex and nPartition Firmware updates for HP Integrity Superdome X Servers with BL920s Gen8 and Gen9 blades. It includes an integrated OA (Onboard Administrator).

WARNING: If you are updating from a version prior to 6.0.42, you must install 6.0.42 (bridge release for digital signing) prior to updating to version 7.5.0 or later.

Note:                                                                                           

Complex Firmware

 

 

5.50.12 1

5.73.0 1

6.0.42

7.5.0

Partition Firmware

5.50.12

Yes

No

No

No

5.73.0

No

Yes

Yes

Yes 1,2,3

6.0.42

No

No

Yes

Yes 2,3

7.5.0

No

No

No

Yes


Note 1:
 Updating Complex FW from 5.X.X to 7.5.0 requires installing 6.0.42 first because of changes to the digital firmware bundle signature.

Note 2: Online Complex FW updates from 6.0.42 to 7.5.0 will show “Mixed” firmware due to newer PDH FPGA in 7.5.0.  Partition operation is supported in this condition. To complete the PDH FPGA update, turn off the partition(s) when convenient, and rerun firmware update.

Note 3: BL920s Gen8 Blades support running Complex FW version 7.5.0 with Partition FW 5.73.0 or 6.0.42, but Gen9 Blades require both Complex and nPartition FW version 7.5.0.

UPDATE RECOMMENDATION: Critical

HP recommends systems used in Mission Critical environments update to this revision of firmware during the next system maintenance period in order to improve system reliability.

[X ] Critical                                                                          

    [X ] Panic, [X ] Hang, [ ] Abort, [ ] Corruption, [ ] Memory Leak,

    [ ] Security

    [ ] Hardware Enablement, [ ] Software Enablement

[ ] Required

[ ] Recommended

[  ] Optional

    [ ] Hardware Enablement, [ ] Software Enablement, [ ] non-critical

[ ] Initial Customer Release

SUPERSEDES:
Bundle version: 6.0.42

PRODUCT MODEL(S):          
HP Integrity Superdome X Servers

OPERATING SYSTEMS:  
Supported OS’es on Gen8 blades:

Supported OS’es on Gen9 blades:

 

LANGUAGES:
International English

 

ENHANCEMENTS:

 

FIXES:

COMPATIBILITY/INTEROPERABILITY:
Note: See the
Firmware Matrix for HP Integrity Superdome X servers for latest information at
http://h20566.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=7161269&docId=emr_na-c04739260

The following IO cards and versions are supported on HP Integrity Superdome X Server:

IO card

Gen8 Blades

Gen9 Blades

Supported OS’es

HP Ethernet 10Gb 2-port 560FLB and  560M Adapter

UEFI: 4.9.10 

Not Supported

Linux, Windows, VMWare

HP QMH2672 16GB Fibre Channel Host Bus Adapter

UEFI 6.37

UEFI 6.37

Gen8: Linux, Windows and VMWare;
Gen9: Linux only

HP FlexFabric 10 Gb 2-port 534M and 534FLB Adapter 1,2

UEFI 7.12.31

Not Supported

Linux only

FlexFabric 20 Gb 2-port 630M and 630FLB card 1,2

Not Supported

UEFI 7.12.31

Linux only

Infiniband HP IB FDR 2-Port 545M card

Not Supported

FW 10.10.50.52
UEFI 14.6.27

Linux only

 

NOTE 1: The HP FlexFabric 2-port 10GB 534M/534FLB and 20GB 630M/630FLB Adapters (Mezzanine and LOM) only provide Ethernet network support.
NOTE 2: FCoE is currently not supported with the I/O Adapters for HP Integrity Superdome X with BL920s Gen8 and Gen9 server blades.

 

      Recommended I/O firmware:

Note:      

 

      Required I/O drivers:

 

A.      Linux 

                                                              i.      Check the HP Servers Support & Certification Matrices for special OS requirements for the HP Integrity Superdome X Server

                                                            ii.      Linux SMH and WBEM providers: HP recommends that you install the latest versions of the SMH and WBEM providers for your SLES or RHEL Operating System from the Software Delivery Repository (SDR). Superdome X providers are available under http://downloads.linux.hp.com/repo/bl920-wbem/
Note: You must install the SMH package prior to the WBEM providers or in the same session.

Note: Reboot is not required for the SMH and WBEM provider changes to take effect.

 

                                                          iii.      Check the Linux white paper for additional details and recommendations.

 

B.      Windows (Supported on Gen8 blades only with this release)
I/O drivers and WBEM providers for Windows 2012 R2 for Superdome X are available as part of the “HP BL920s Gen8 Windows Drivers Bundle” (latest version) on the Superdome X download page on HP Support Center, under “Software – Support Pack”. Follow the instructions in the bundle to install the components.

For more information on installing Windows OS and components on Superdome X, see the Windows white paper “Running Microsoft Windows Server on HP Integrity Superdome X”, at http://h20195.www2.hp.com/v2/GetDocument.aspx?docname=4AA5-7519ENW&doctype=Technical white paper.

 

PREREQUISITES:

WARNING:

 

HP strongly recommends implementing the following security best practices to help reduce both known and future security vulnerability risks:

1.       Isolate the management network by keeping it separate from the production network and not putting it on the open internet without additional access authentication.

2.       Patch and Maintain LDAP and web servers.

3.       Run the up-to-date viruses and malware scanners in your network environment

4.       Apply HP Firmware updates as recommended.

 

INSTALLATION INSTRUCTIONS:

Please review all instructions and the " Hewlett Packard Enterprise Support Tool License Terms" or your Hewlett Packard Enterprise support terms and conditions for precautions, scope of license, restrictions, and limitation of liability and warranties, before installing this package. It is important that you read and understand these instructions completely before you begin. This can determine your success in completing the firmware update.

These instructions describe how to install the firmware version 7.5.0. The list below is a summary of the steps to install the firmware.

A.       Downloading the bundle

B.       Updating Complex firmware using OA CLI  

C.     Updating specific nPartition firmware using OA CLI (optional)

D.       Updating IO firmware, SMH and WBEM providers


NOTE:
For more details, review the “HP Integrity Superdome X and Superdome 2 Onboard Administrator Command Line Interface User Guide”. 

Update Superdome X Complex from Firmware Bundle using Onboard Administrator's Command Line Interface (CLI)

A. Downloading the bundle

1.       Download the file hpsdx-7.5.0-fw.bundle in a new folder in your desktop.

2.       Copy the bundle file to a USB Key or to a FTP Server reachable from Onboard Administrator.

NOTE: If you are using FTP, then please make sure the transfer mode is set to "Binary".

Note:

B. Updating Superdome X Complex and nPartition firmware using OA CLI

1.       Connect to Onboard Administrator over Telnet or SSH and login to get the command line prompt.

NOTE: Only in case of offline firmware update, do the following steps a. and b. below, otherwise skip to step 2 for online firmware update. Offline update requires downtime for the entire server. Online update is recommended for servers with firmware versions 5.73.0 or later (skip a. and b. and go directly to step 2 for online update).

Offline update:

a. Gracefully shutdown OS in each partition, using shutdown -h, as forcing partition power off is likely to corrupt OS.

b. Power down all blades using the following command (not required if performing an online firmware update):
     OA1-CLI> POWEROFF PARTITION X FORCE OVERRIDE
This may take some time and it asks for confirmation status for partitions before moving on. You can use the following command to confirm status of partitions:
      OA1-CLI> parstatus –P


NOTE:
The update procedure for online update of complex firmware on systems with firmware version 5.73.0 or later starts here.

2. Verify communications between the OA and all installed Blades, using the connect blade command for each of the installed Cell Blades.
NOTE:  If the OA to any blade communications is not working, update firmware will fail.

                      sd-oa1> connect blade 1

                      Connecting to bay 1 ...

          User:OAtmp-Administrator-53A9 logged-in to ILO-B.hp.com(16.11.18.7 / FE80)
   iLO 4 Standard Blade Edition 1.50 at  Apr 29 2014
Server Name: sd-oa1
Server Power: On 

3. Use the update firmware command, as shown below, to point to Integrated Firmware Update Bundle at a valid ftp location.

OA1-CLI> UPDATE FIRMWARE <uri> all

NOTE: The "all" option must be used in order to update complex AND partition firmware

             Where The <uri> should be formatted as usb://<path> for USB installations. Use the SHOW
             USBKEY command to obtain the <path>.

Example:

Using FTP:

update firmware ftp://user:passwd@15.1.1.75/firmware/hpsdx-7.5.0-fw.bundle all

Using USB Key:

update firmware usb://d2/ hpsdx-7.5.0-fw.bundle all

NOTE: The Firmware update process can take up to 1 hour to complete. During this process you might notice no progress for up to 30 minutes at certain time. In between the updates, connection to OA will be lost as OA will reboot to proceed towards other firmware updates. OA might take up to 30 minutes to come to ready state after the reboot. After OA is rebooted you can reconnect back to OA and login to confirm successful update.

4.       Run the OA command UPDATE SHOW FIRMWARE to display the versions of complex bundle last installed and firmware versions installed.

Example:

OA1-CLI> UPDATE SHOW FIRMWARE

Configured complex firmware bundle version: 7.5.0

====================================================================

Firmware on all devices matches the complex configured bundle version
Note: Partition firmware activation requires a partition reboot (see step C. 5.).

5.       Verify all partitions are ready to be started using:

parstatus -P command (this command will not work until the OA restart is complete)

NOTE: Step 6 is only needed in case of offline firmware update (steps 1. a. and b. above)

6. Power on the complex using poweron partition [X] for each of the nPartitions.

C. Updating specific nPartition firmware using OA CLI (optional)

    Note: Step C is not needed if you have updated both complex and all partition firmware in step B above. 

1.       Connect to Onboard Administrator over Telnet or SSH and login to get the command line prompt.

2.       Run the OA command UPDATE SHOW NPARTITION ALL to display the versions of partition firmware installed.

Example:

OA1-CLI> UPDATE SHOW NPARTITION ALL

nPartition firmware version applied to partition 1 nPar0001

Configured nPartition Firmware Version: 7.5.0

Active nPartition Firmware Version: 7.5.0

nPartition firmware on all blades matches the partition's configured version

 

3.       Use the update npartition command, as shown below, to point to Integrated Firmware Update Bundle at a valid ftp location and update the desired partition, taking into account planned downtime for OS update and reboot.

OA1-CLI> UPDATE NPARTITION <npar name or number> <uri>

Where <npar name or number> is the partition whose nPartition firmware should be updated.

The <uri> should be formatted as usb://<path> for USB installations. Use the SHOW USBKEY command to obtain the <path>.

Examples:

Using FTP:

update npartition 1 ftp://user:passwd@15.1.1.75/firmware/hpsdx-7.5.0-fw.bundle

Using USB Key:

update npartition 1 usb://d2/hpsdx-7.5.0-fw.bundle

4.       Repeat step 2 to verify that the requested update was successfully

5.       Restart nPar to activate partition firmware (when ready for Partition downtime)

Note: if nPartition firmware was updated in step B, but not activated, shut down all running OSs in the nPar then power off the nPar, then power on the nPar. The nPar restart will cause the updated nPartition firmware to be activated. The following sequence can be used:

OA1-CLI>POWEROFF PARTITION< npar#> OVERRIDE

OA1-CLI> POWEROFF PARTITION< npar#> FORCE OVERRIDE

OA1-CLI> POWERON PARTITION <npar#>

       Run the OA command UPDATE SHOW NPARTITION ALL to display the versions of partition firmware installed.

Example:

OA1-CLI> UPDATE SHOW NPARTITION ALL

D. Updating IO firmware, SMH and WBEM providers

See the section COMPATIBILITY/INTEROPERABILITY section for supported IO cards, WBEM providers, and supported versions.

DETERMINING CURRENT VERSION:

KNOWN ISSUES & WORKAROUNDS:

DISCLAIMER:
The information in this document is subject to change without notice.

Hewlett Packard Enterprise makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett Packard Enterprise shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.

This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be reproduced, photocopied, or translated to another language without the prior written consent of Hewlett Packard Enterprise.

(C) Copyright 2015 Hewlett Packard Enterprise Development L.P.

FEEDBACK
As we are continuing to improve the firmware management process we welcome your feedback on this document and on the firmware update process: TEAM-FWupdateFeedback@groups.ext.hpe.com